LC/SC/FC/ST/MU/E2000/MTRJ yagona rejimli dupleks 9/125 OS1/OS2 optik patch kabeli
Mahsulot tavsifi
Yagona rejimli patch kordlari juda kichik diametrli yadroga ega bo'lib, u faqat bitta yorug'lik rejimidan o'tishga imkon beradi. Buning natijasida yadro bo'ylab harakatlanadigan yorug'lik natijasida paydo bo'ladigan ko'zgular soni keskin kamayadi.Bu o'z navbatida zaiflashuvni pasaytiradi va signalning tezroq va uzoqroq harakatlanishiga imkon beradi.Agar bu yordam bersa, uni juda yupqa shlang trubkasi orqali oqib o'tadigan suv nuqtai nazaridan o'ylab ko'ring, u kattaroq shlangdan ko'ra ko'proq siqiladi, tezroq va kichikroq shlang orqali o'tadi.
Yagona rejimli dupleks OS1/OS2 9/125 mkm optik tolali patch kabellari turli uzunlikdagi, ko'ylagi materiali, jilo va kabel diametrining ko'p tanloviga ega.U yuqori sifatli Yagona rejimli optik tolali va seramika konnektorlari bilan ishlab chiqariladi va tolali kabel infratuzilmasi uchun yuqori ishlashni ta'minlash uchun kiritish va qaytarish yo'qolishi uchun qat'iy sinovdan o'tkaziladi.Shuningdek, u ma'lumotlar markazlarida, korporativ tarmoqlarda, telekommunikatsiya xonasida, server fermalarida, bulutli saqlash tarmoqlarida va tolali patch kabellari kerak bo'lgan har qanday joylarda yuqori zichlikdagi kabellar uchun ko'proq joyni tejash imkonini beradi.
Ushbu 9/125 mkm OS1/OS2 yagona rejimli optik tolali kabel 1G/10G/40G/100G/400G Ethernet ulanishlarini ulash uchun ideal.U 1310nm da 10km gacha yoki 1550nm da 40km gacha maʼlumotlarni uzatishi mumkin.
Mahsulot spetsifikatsiyasi
Elyaf rejimi | OS1/OS2 9/125 mikron | To'lqin uzunligi | 1310/1550nm |
Qo'shishni yo'qotish | ≤0,3dB | Yo'qotishlarni qaytarish | UPC≥50dB;APC≥60dB |
Min.Bend radiusi (tolali yadro) | 10 mm | Min.Bend radiusi (tolali kabel) | 10D/5D (Dinamik/Statik) |
1310 nm da zaiflashuv | 0,36 dB/km | 1550 nm da zaiflashuv | 0,22 dB/km |
Elyaflar soni | Ikki tomonlama | Kabel diametri | 1,6 mm, 1,8 mm, 2,0 mm, 3,0 mm |
Kabel ko'ylagi | LSZH, PVX (OFNR), Plenum (OFNP) | Polarlik | A(Tx) dan B(Rx) |
Ishlash harorati | -20~70°C | Saqlash harorati | -40~80°C |
LC/UPC-LC/UPC yagona rejimli dupleks
![LC dan LC ga yagona rejimli dupleks-1](http://www.raisefiber.com/uploads/LC-to-LC-Single-Mode-Duplex-1.jpg)
![LC dan LC ga yagona rejimli dupleks-2](http://www.raisefiber.com/uploads/LC-to-LC-Single-Mode-Duplex-2.jpg)
LC/UPC-SC/UPC yagona rejimli dupleks
![LC to SC Single Mode Duplex-1](http://www.raisefiber.com/uploads/LC-to-SC-Single-Mode-Duplex-1.jpg)
![LC dan SCga yagona rejimli dupleks-2](http://www.raisefiber.com/uploads/LC-to-SC-Single-Mode-Duplex-2.jpg)
LC/UPC-FC/UPC yagona rejimli dupleks
![LC to FC Single Mode Duplex-1](http://www.raisefiber.com/uploads/LC-to-FC-Single-Mode-Duplex-1.jpg)
![LC to FC Single Mode Duplex-2](http://www.raisefiber.com/uploads/LC-to-FC-Single-Mode-Duplex-2.jpg)
LC/UPC-ST/UPC yagona rejimli dupleks
![LC UPC dan ST UPCga yagona rejimli dupleks-1](http://www.raisefiber.com/uploads/LC-UPC-to-ST-UPC-Single-Mode-Duplex-1.jpg)
![LC UPC dan ST UPC ga yagona rejimli dupleks-2](http://www.raisefiber.com/uploads/LC-UPC-to-ST-UPC-Single-Mode-Duplex-2.jpg)
FC/UPC-ST/UPC yagona rejimli dupleks
![FC UPC-ST UPC yagona rejimli dupleks](http://www.raisefiber.com/uploads/FC-UPC-ST-UPC-Single-Mode-Duplex.jpg)
![FC UPC-ST UPC yagona rejimli dupleks-2](http://www.raisefiber.com/uploads/FC-UPC-ST-UPC-Single-Mode-Duplex-2.jpg)
SC/UPC-SC/UPC yagona rejimli dupleks
![SC UPC-SC UPC yagona rejimli dupleks-1](http://www.raisefiber.com/uploads/SC-UPC-SC-UPC-Single-Mode-Duplex-1.jpg)
![SC UPC-SC UPC yagona rejimli dupleks-2](http://www.raisefiber.com/uploads/SC-UPC-SC-UPC-Single-Mode-Duplex-2.jpg)
LC/APC-SC/APC yagona rejimli dupleks
![LC APC dan SC APCga yagona rejimli dupleks-1](http://www.raisefiber.com/uploads/LC-APC-to-SC-APC-Single-Mode-Duplex-1.jpg)
![LC APC dan SC APCga yagona rejimli dupleks-2](http://www.raisefiber.com/uploads/LC-APC-to-SC-APC-Single-Mode-Duplex-2.jpg)
LC/APC-LC/APC yagona rejimli dupleks
![LC APC yagona rejimli dupleks-1](http://www.raisefiber.com/uploads/LC-APC-Single-Mode-Duplex-1.jpg)
![LC APC yagona rejimli dupleks-2](http://www.raisefiber.com/uploads/LC-APC-Single-Mode-Duplex-2.png)
SC/APC-ST/UPC yagona rejimli dupleks
![SC APC dan ST Single Mode Duplex-1 ga](http://www.raisefiber.com/uploads/SC-APC-to-ST-Single-Mode-Duplex-1.jpg)
![SC APC dan ST Single Mode Duplex-2 ga](http://www.raisefiber.com/uploads/SC-APC-to-ST-Single-Mode-Duplex-2.jpg)
SC/UPC-ST/UPC yagona rejimli dupleks
![SC dan STga yagona rejimli dupleks-1](http://www.raisefiber.com/uploads/SC-to-ST-Single-Mode-Duplex-1.jpg)
![SC dan STga yagona rejimli dupleks-2](http://www.raisefiber.com/uploads/SC-to-ST-Single-Mode-Duplex-2.jpg)
Moslashtirilgan LC/SC/ST/FC APC dupleks yagona rejimli OS1/OS2 9/125 optik tolali patch kabeli
![LC APC dan FC APC ga yagona rejimli tolali kabel-2](http://www.raisefiber.com/uploads/LC-APC-to-FC-APC-Single-Mode-Fiber-Cable-2.jpg)
![LC APC dan SC APC ga yagona rejimli tolali kabel-1](http://www.raisefiber.com/uploads/LC-APC-to-SC-APC-Single-Mode-Fiber-Cable-1.jpg)
Moslashtirilgan LC/SC/ST/FC UPC dupleks yagona rejimli OS1/OS2 9/125 optik tolali patch kabeli
![FC UPC ST UPC yagona rejimli ulagich-1](http://www.raisefiber.com/uploads/FC-UPC-ST-UPC-Single-Mode-Connector-1.jpg)
![FC UPC ST UPC yagona rejimli ulagich-2](http://www.raisefiber.com/uploads/FC-UPC-ST-UPC-Single-Mode-Connector-2.jpg)
Moslashtirilgan ulagich turi: LC/SC/FC/ST/E2000
![Moslashtirilgan ulagich turi](http://www.raisefiber.com/uploads/Customized-Connector-Type5.jpg)
Sanoat standarti tolali optik kabel
Optik tolali kabel yuqori tezlikdagi kabel tarmoqlari uchun EIA/TIA 604-2 ga javob beradigan sanoat standarti yonuvchanlik darajasiga ega PVX ko'ylagi va dupleks tolali ulagichga ega.
![Sanoat standarti tolali optik kabel](http://www.raisefiber.com/uploads/Industry-Standard-Fiber-Optic-Cable.jpg)
Kengaytirilgan B darajali LC Data Center Premium Patch kabeli
Ultra kiritish yo'qolishi |Corning tolasi |Kamaytirilgan egilish sezgirligi |IEC, EIA/TIAga mos keladi
![Kengaytirilgan B darajali LC Data Center Premium Patch kabeli](http://www.raisefiber.com/uploads/Enhanced-Grade-B-LC-Data-Center-Premium-Patch-Cable.jpg)
Premium tasodifiy juftlashuvchi IL ishlashi
B toifali kabellarni bir-biri bilan kesishgan holda, IL boshqa darajali ulagichga qaraganda barqarorroq va master jumper bilan sinovdan o'tgan IL ga yaqin.
![Kengaytirilgan B darajali LC Data Center Premium Patch Cable-2](http://www.raisefiber.com/uploads/Enhanced-Grade-B-LC-Data-Center-Premium-Patch-Cable-2.jpg)
Corning Bend sezgir tolasi
An'anaviy tolali kabellarga qaraganda ancha kamroq signal yo'qotilishi bilan qattiq egilishlarga va qiyin kabel yo'nalishlariga bardosh berish uchun mo'ljallangan.
![Kengaytirilgan B darajali LC Data Center Premium Patch Cable-3](http://www.raisefiber.com/uploads/Enhanced-Grade-B-LC-Data-Center-Premium-Patch-Cable-3.jpg)
Aqlli va ishonchli - bukiladigan optik tolali
Bend sezgir bo'lmagan optik tolali kabel sanoat standarti yonuvchanlik darajasiga ega PVX ko'ylagi va yuqori tezlikdagi kabel tarmoqlari uchun EIA/TIA 604-2 ga javob beradigan dupleks tolali ulagichga ega.
![Bukiladigan optik tolali](http://www.raisefiber.com/uploads/Bendable-Optical-Fiber.jpg)
![G.657.A1 Bend sezgir tolasi](http://www.raisefiber.com/uploads/G.657.A1-Bend-Insensitive-Fiber.jpg)
G.657.A1 Bend sezgir tolasi
BIF kabeli ishlashni yo'qotmasdan zımbalansa va burchaklarga egilishi mumkin.
![Minimal egilish radiusi 10 mm](http://www.raisefiber.com/uploads/10mm-Minimum-Bend-Radius.jpg)
Minimal egilish radiusi 10 mm
Bükme ishlashi kanallardan foydalanishni yaxshilaydi, bu esa kichikroq korpuslarga imkon beradi.
![Zirkonli keramik ferrul](http://www.raisefiber.com/uploads/Zirconia-Ceramic-Ferrule1.jpg)
Zirkonli keramik ferrul
Optimal IL va RL barqaror signal uzatilishini ta'minlaydi va tarmoq xavfsizligini himoya qiladi.
LC konnektorlari
![LC konnektorlari](http://www.raisefiber.com/uploads/LC-connectors.jpg)
Ushbu ulagichlar kichik o'lchamlari tufayli yuqori zichlikdagi ilovalarda foydalanish uchun idealdir va tortishga chidamli dizaynga ega.Ular 1,25 mm tsirkonli ferrulga ega oddiy va dupleks versiyalarda mavjud.Bundan tashqari, LC konnektorlari raf moum ichida barqarorlikni ta'minlash uchun maxsus mandal mexanizmidan ham foydalanadi.
SC ulagichlari:
![SC ulagichlari](http://www.raisefiber.com/uploads/SC-connectors.jpg)
SC konnektorlari 2,5 mm oldindan radiusli tsirkonli ferrulga ega optik bo'lmagan ajratuvchi ulagichlardir.Ular surish xususiyatiga ega bo'lganligi sababli kabellarni tokchaga yoki devorga o'rnatish moslamalariga tezda yopishtirish uchun idealdir.Ikki tomonlama ulanishga ruxsat berish uchun qayta foydalanish mumkin bo'lgan dupleks ushlagich bilan simpleks va dupleks mavjud.
FC ulagichlari:
![FC konnektorlari](http://www.raisefiber.com/uploads/FC-connectors.jpg)
Ular bardoshli tishli muftaga ega va telekommunikatsiya ilovalarida foydalanish uchun eng mos keladi va optik bo'lmagan uzilishdan foydalanadi.
ST konnektorlari:
![ST konnektorlari](http://www.raisefiber.com/uploads/ST-connectors.jpg)
ST konnektorlari yoki To'g'ri uchli konnektorlar 2,5 mm ferrulli yarim noyob nayzali ulanishdan foydalanadi.STlar ishonchliligi va chidamliligi tufayli dala o'rnatish uchun ajoyib optik tolali ulagichlardir.Ular oddiy va dupleksda mavjud
Ishlash testi
![Ishlash testi](http://www.raisefiber.com/uploads/Performance-Test1.jpg)
Ishlab chiqarish rasmlari
![Ishlab chiqarish rasmlari](http://www.raisefiber.com/uploads/Production-Pictures.jpg)
Zavod rasmlari
![Haqiqiy zavod rasmlari](http://www.raisefiber.com/uploads/Factory-Real-Pictures1.jpg)